This guide shows you how to properly clean the BXT3 battery powered strapping tool tooth plate in the event it clogs up with strapping.
Dismantling
► Remove battery from tool.
► Remove counter-sunk screw Torx (1).
► Lift rocker lever towards the handle, remove tooth plate (2). WARNING Wear eye protection when cleaning with compressed air!
► Clean tooth plate (2) with compressed air.
► In the case of heavy soiling of the teeth: Carefully clean tooth plate with enclosed wire brush (3).
► Check tooth plate for worn teeth. If several teeth are worn, replace tooth plate. Fitting
► Fitting is performed in reverse order. Secure counter-sunk screw (1) with Loctite 222.
– The tooth plate (2 ) must sit freely movable in the rocker